20426984, 2021, 3, Downloaded from https://onlinelibrary.wiley.com/doi/10.1002/alr.22741 by Stanford University, Wiley Online Library on [01/07/2024]. See the Terms and Conditions (https://onlinelibrary.wiley.com/terms-and-conditions) on Wiley Online Library for rules of use; OA articles are governed by the applicable Creative Commons License
600
International consensus statement on rhinosinusitis
(Continues)
Accuracy All approaches yielded accuracy < 1mm;
Complication rates Major ESS complications seem to be decreasing;
impact of IGS is unclear.
Bergeron 2125 2015 4 Case series ESS with IGS in children (n = 21) and adults (n = 38) Complications, accuracy IGS is comparable in adults and children
Description of techniques IGS is faster, safer and more exact that fluoroscopy
Servat 2120 2014 4 Case series Endoscopic orbital surgery with IGS Complications, effectiveness IGS aids endoscopic orbital surgery. Eloy 2138 2013 4 Medicolegal case review 30 malpractice cases; 4 mentioned IGS Mentions of IGS in
Accuracy Novel device offers more robust accuracy
bone-anchored fiducials were best, followed by
contour and then mask
Glicksman 2086 2017 3 Cohort study Comparison of 2 registration types in 45 patients: 1. Contour-based 2. Facial recognition Accuracy Facial recognition registration was better than
contour-based registration.
Lam 2143 2017 4 Case series Microsensor navigation with balloon sinus surgery (n = 18 sinuses) Effectiveness Microsensors may be combined with sinus balloons.
Al-Qudah 2126 2015 4 Case series ESS with IGS in patients with skull base and orbital erosion (n = 14) Complications, effectiveness IGS is safe and effective during ESS in patients with skull base erosion.
Jiang 2121 2014 4 Case series Endoscopic sphenoidotomy with IGS (n = 30) Effectiveness, safety IGS facilities endoscopic sphenoidotomy
IGS is not a factor in ESS litigation.
Stokken 2119 2015 4 Case series Endoscopic orbital surgery cases (n = 27) Outcomes IGS should be employed for complex endoscopic orbital cases. Taulu 2128 2015 4 Case series Device placement with fluoroscopy (n = 26) and IGS (n = 26)
Study Year LOE Study Design Study Groups Clinical Endpoint Conclusions
malpractice judgments
Ramakrishnan 2150 2013 4 Database query 62,823 patients undergoing ESS (identified in
MarketScan Commercial Claims and Encounters database)
Grauvogel 2148 2017 3 Dry lab Comparison of 3 registration types in cadaveric lab: 1. Paired point against
bone-anchored fiducials 2. LEDmask
patient tracker tested in lab
3. Contour-mapping
Wellborn 2149 2017 4 Dry lab Novel set-up for fixation of